Before you begin

Icon for electrostatic discharge wrist strapUse approved ESD procedures to prevent damage.

Attention:
  • This procedure is not a stand-alone procedure. Customer disruption and damage to the hardware might occur when microcode and power boundaries are not in the proper conditions for this service action.
  • If a serviceable event FRU repair directed you to this procedure, the microcode and power boundaries are already set.
  • If a serviceable event FRU repair did not direct you to this procedure, see MAP1230 Replace a FRU without using a serviceable event.
Notes:
  • All the cables and FRUs to be removed must be uniquely identified so they can be reinstalled correctly.
  • If an installed earthquake resistance kit prevents you from accessing this FRU, refer to MAP1600 If earthquake resistance kit parts prevent you from servicing a rack.
  • The power, VGA and USB cables are part of the keyboard/display assembly. They cannot be removed from the assembly.
  • The FRU kit includes a cable routing tool to assist with routing the cables through the rack.

Remove the management console keyboard and display drawer

Procedure

  1. At the front left of Rack-1, pull the management console keyboard and display drawer out to the service position and open the keyboard tray.
  2. Confirm that the monitor is powered off. If not, press the power button at the lower right of the monitor.
  3. Disconnect the keyboard and monitor cables from the USB and VGA connectors on the patch panel that is located just below the keyboard/display drawer.
  4. Unfasten the patch panel from the rack. Leave the USB and VGA cables attached to the rear of the patch panel.
  5. Observe the routing of the keyboard and monitor cables from inside the rack to the front of the patch panel.
  6. Carefully pull the keyboard and monitor cables back into the space behind the patch panel opening.
  7. At the rear of the rack, disconnect the monitor power cable from the J9 connectors on PJA E41 and PJA E42. See Figure 1.
    Figure 1. Power junction assembly (PJA) locations (models 980, 981, 982)
    Model 98x power junction assembly (PJA) locations
    Note: The PJA shown in Figure 1 is for models 980, 981, and 982. J6 and J8 are not present on the PJA for models 984, 985, 986, and 988.
  8. Observe the routing of the monitor power cable assembly through the channel at the right rear of the rack.
  9. Unfasten the cable retention hardware as needed. Carefully pull the monitor power cable assembly through the channel to the front of the rack.
  10. At the front of the rack, close the keyboard tray.
  11. Release the top and bottom latch of the keyboard/display drawer.
  12. Remove the keyboard and display drawer, with cables, from the rails.

Install the management console keyboard and display drawer

Procedure

  1. Install the new keyboard and display drawer assembly onto the rails.
  2. Route the monitor power cable assembly from the keyboard and display drawer to the rear of the rack.
    1. Use the provided cable routing tool as needed.
    2. Follow the routing method you observed before disconnecting the cables.
    3. Do not connect the cables to the PJAs now.
  3. At the front of the rack, route the USB and VGA cables from the keyboard and display drawer into the side of the rack and through the patch panel opening.
    Use the provided cable routing tool as needed.
  4. Install and fasten the patch panel. Keep the USB and VGA connectors (from the keyboard/display drawer) outside the patch panel.
  5. Connect the keyboard and monitor cables to the primary management console (MC 1) ports. The MC 1 ports are the upper USB and VGA connectors on the patch panel.
  6. At the rear of the rack, connect the monitor power cables to the J9 connectors on PJA E41 and PJA E42. See Figure 1. Fasten cable retention hardware as needed.
  7. At the front of the rack, confirm that the monitor is powered on. If not, press the power button at the lower right of the monitor.
  8. Close the keyboard tray and return the management console keyboard and display drawer to the operating position, as required. Secure the tray as needed.