FC-AL cables - Models 951, 95E (business class)
Use the point-to-point cabling diagrams below to route the FC-AL cables on a Model 951, with or without expansion racks.
- Racks are shown with the maximum number of storage enclosures and device adapter cards. Your rack might contain fewer storage enclosures or device adapter cards.
- The figures that follow show the maximum number of racks in a storage facility with these rack models.
- FC-AL cables and connectors are identified with two
different color codes and a location designator:
- A colored band, corresponding to the color code of the DA pair, is found on each end of the cable near the connector. These color codes are shown in Figure 2.
- The connector itself is color coded to help prevent cross-cabling
at the Fibre Channel interface card (FCIC) or device adapter card
(DA) end. The connectors will always appear in the following order:
as shown in Figure 3 and Figure 4. This color code is specific to each FCIC or DA, and is independent of the DA pair color code.beige (T1), green (T2), black (T3), and blue (T4) - A black or white label at each end of the cable shows a location designator (for example, 0A2). Both ends of the cable will have the same location designator and DA pair color code. However, the connector at each end of the same cable will usually NOT have the same color code.
- Location designators are in the form CTP, where:
- C
- is the device adapter pair (0-7)
- T
- is the port pair on the device adapter (A, B, C, D, a, b, c, d) (uppercase for left device adapter in pair, lowercase for right device adapter in pair).
- P
- is the logical position of the downstream FCIC in the loop.
Example: 2a1 is the link between device adapter R1-XI4-C6-T1 and R1-G09-C1-T2.- 2
- device adapter pair 2
- a
- first port pair on right adapter of device adapter pair (lowercase a)
- 1
- first FCIC on loop of this port pair
- Some connectors are for cables that would go to an optional expansion rack. In that case, only one instance of that designator is on the rack.
- The black and white label at each end may have a physical
location code in addition to the location designator.
- If the cable connects to an I/O enclosure device adapter card connector, the physical location code will be similar to this example: R1-XC1-P1-C1-T1. Refer to I/O enclosure location codes (Models 951, 95E).
- If the cable connects to a storage enclosure Fibre Channel interface card, the physical location code will be similar to this example: R1-G01-P1-C1-T1. Refer to Storage enclosure location codes (Models 951, 95E).
- There are two FC-AL cable configurations for Rack-1:
- Standard for Rack Configuration: AE1
- Business class for Rack Configuration: AB1
Figure 1. Rack-1 configuration labels 



Cabling tables
From: DA Pair |
DA Pair (link) |
To: Storage Enclosure |
To: Storage Enclosure |
To: Storage Enclosure |
|---|---|---|---|---|
R1-XI3-P1-C3-T1/T2 R1-XI4-P1-C6-T1/T2 |
2 (A) 2 (a) |
R1-G09 |
R1-G01 |
R1-G07 |
R1-XI3-P1-C3-T3/T4 R1-XI4-P1-C6-T3/T4 |
2 (B) 2 (b) |
R1-G10 |
R1-G02 |
R1-G08 |
R1-XI3-P1-C6-T1/T2 R1-XI4-P1-C3-T1/T2 |
3 (A) 3 (a) |
R1-G05 |
R1-G03 |
(none) |
R1-XI3-P1-C6-T3/T4 R1-XI4-P1-C3-T3/T4 |
3 (B) 3 (b) |
R1-G06 |
R1-G04 |
(none) |
From: FCIC |
link | To: FCIC |
|---|---|---|
| DA pair 2 | ||
| R1-G01-P1-C1-T3 | 2A5 | R1-G07-P1-C1-T1 |
| R1-G01-P1-C1-T4 | 2a5 | R1-G07-P1-C1-T2 |
| R1-G01-P1-C2-T3 | 2A6 | R1-G07-P1-C2-T1 |
| R1-G01-P1-C2-T4 | 2a6 | R1-G07-P1-C2-T2 |
| R1-G02-P1-C1-T3 | 2B5 | R1-G08-P1-C1-T1 |
| R1-G02-P1-C1-T4 | 2b5 | R1-G08-P1-C1-T2 |
| R1-G02-P1-C2-T3 | 2B6 | R1-G08-P1-C2-T1 |
| R1-G02-P1-C2-T4 | 2b6 | R1-G08-P1-C2-T2 |
| DA pair 3 | ||
| R1-G05-P1-C1-T3 | 3A3 | R1-G03-P1-C1-T1 |
| R1-G05-P1-C1-T4 | 3a3 | R1-G03-P1-C1-T2 |
| R1-G05-P1-C2-T3 | 3A4 | R1-G03-P1-C2-T1 |
| R1-G05-P1-C2-T4 | 3a4 | R1-G03-P1-C2-T2 |
| R1-G06-P1-C1-T3 | 3B3 | R1-G04-P1-C1-T1 |
| R1-G06-P1-C1-T4 | 3b3 | R1-G04-P1-C1-T2 |
| R1-G06-P1-C2-T3 | 3B4 | R1-G04-P1-C2-T1 |
| R1-G06-P1-C2-T4 | 3b4 | R1-G04-P1-C2-T2 |
From: DA |
link |
To: FCIC |
From: FCIC |
link |
To: FCIC |
|
|---|---|---|---|---|---|---|
R1-XI3-P1-C3-T1 |
2A1 |
R1-G09-P1-C1-T1 |
R1-G09-P1-C1-T3 |
2A3 |
R1-G01-P1-C1-T1 |
|
R1-XI4-P1-C6-T1 |
2a1 |
R1-G09-P1-C1-T2 |
R1-G09-P1-C1-T4 |
2a3 |
R1-G01-P1-C1-T2 |
|
R1-XI3-P1-C3-T2 |
2A2 |
R1-G09-P1-C2-T1 |
R1-G09-P1-C2-T3 |
2A4 |
R1-G01-P1-C2-T1 |
|
R1-XI4-P1-C6-T2 |
2a2 |
R1-G09-P1-C2-T2 |
R1-G09-P1-C2-T4 |
2a4 |
R1-G01-P1-C2-T2 |
|
R1-XI3-P1-C3-T3 |
2B1 |
R1-G10-P1-C1-T1 |
R1-G10-P1-C1-T3 |
2B3 |
R1-G02-P1-C1-T1 |
|
R1-XI4-P1-C6-T3 |
2b1 |
R1-G10-P1-C1-T2 |
R1-G10-P1-C1-T4 |
2b3 |
R1-G02-P1-C1-T2 |
|
R1-XI3-P1-C3-T4 |
2B2 |
R1-G10-P1-C2-T1 |
R1-G10-P1-C2-T3 |
2B4 |
R1-G02-P1-C2-T1 |
|
R1-XI4-P1-C6-T4 |
2b2 |
R1-G10-P1-C2-T2 |
R1-G10-P1-C2-T4 |
2b4 |
R1-G02-P1-C2-T2 |
|
From: FCIC |
link |
To: FCIC |
||||
R1-G01-P1-C1-T3 |
2A5 |
R1-G07-P1-C1-T1 |
||||
R1-G01-P1-C1-T4 |
2a5 |
R1-G07-P1-C1-T2 |
||||
R1-G01-P1-C2-T3 |
2A6 |
R1-G07-P1-C2-T1 |
||||
R1-G01-P1-C2-T4 |
2a6 |
R1-G07-P1-C2-T2 |
||||
R1-G02-P1-C1-T3 |
2B5 |
R1-G08-P1-C1-T1 |
||||
R1-G02-P1-C1-T4 |
2b5 |
R1-G08-P1-C1-T2 |
||||
R1-G02-P1-C2-T3 |
2B6 |
R1-G08-P1-C2-T1 |
||||
R1-G02-P1-C2-T4 |
2b6 |
R1-G08-P1-C2-T2 |
From: DA |
link |
To: FCIC |
From: FCIC |
link |
To: FCIC |
|
|---|---|---|---|---|---|---|
R1-XI3-P1-C6-T1 |
3A1 |
R1-G05-P1-C1-T1 |
R1-G05-P1-C1-T3 |
3A3 |
R1-G03-P1-C1-T1 |
|
R1-XI4-P1-C3-T1 |
3a1 |
R1-G05-P1-C1-T2 |
R1-G05-P1-C1-T4 |
3a3 |
R1-G03-P1-C1-T2 |
|
R1-XI3-P1-C6-T2 |
3A2 |
R1-G05-P1-C2-T1 |
R1-G05-P1-C2-T3 |
3A4 |
R1-G03-P1-C2-T1 |
|
R1-XI4-P1-C3-T2 |
3a2 |
R1-G05-P1-C2-T2 |
R1-G05-P1-C2-T4 |
3a4 |
R1-G03-P1-C2-T2 |
|
R1-XI3-P1-C6-T3 |
3B1 |
R1-G06-P1-C1-T1 |
R1-G06-P1-C1-T3 |
3B3 |
R1-G04-P1-C1-T1 |
|
R1-XI4-P1-C3-T3 |
3b1 |
R1-G06-P1-C1-T2 |
R1-G06-P1-C1-T4 |
3b3 |
R1-G04-P1-C1-T2 |
|
R1-XI3-P1-C6-T4 |
3B2 |
R1-G06-P1-C2-T1 |
R1-G06-P1-C2-T3 |
3B4 |
R1-G04-P1-C2-T1 |
|
R1-XI4-P1-C3-T4 |
3b2 |
R1-G06-P1-C2-T2 |
R1-G06-P1-C2-T4 |
3b4 |
R1-G04-P1-C2-T2 |