I/O enclosure (2U) part numbers (Model 983)
Information about 2U I/O enclosure parts is listed below. Use Table 1 as a directory.
Note: The following part numbers are the most recent for this version of the
Parts Catalog. Your storage facility or serviceable event FRU list might contain an older or newer
part number. The parts-ordering system recognizes all valid part numbers and automatically
substitutes an available part number as needed.
| Part name | Figure |
|---|---|
| I/O enclosure (2U) fan | Figure 1 |
| I/O enclosure (2U) front bezel | Figure 1 |
| I/O enclosure (2U) power supply | Figure 1 |
| I/O enclosure (2U) adapter (Fibre Channel host) | Figure 5 |
| I/O enclosure (2U) adapter (PCIe) | Figure 4 |
| I/O enclosure (2U) adapter (PCIe and SAS device) | Figure 3 |
| I/O enclosure (2U) adapter (PCN) | Figure 6 |
| I/O enclosure (2U) midplane assembly | Figure 2 |
| All other parts | (Find the appropriate figure below) |

| Index | Part name | CCIN1 | Part number |
|---|---|---|---|
| A1, A2 | Fan | 02AN058 | |
| Not shown | Front bezel | 02AN734 | |
| E1, E2 | Power supply | 01KL609 | |
|
Notes:
|
|||
| Location | I/O enclosure part name | CCIN1 | Part number |
|---|---|---|---|
| P1 | I/O enclosure (2U) midplane assembly Figure 2 |
02AN688 | |
| P1-C1 P1-C8 |
I/O enclosure (2U) adapter (PCIe and SAS device) Figure 3 |
2E0E | 02AN008 |
| P1-C2 P1-C7 |
I/O enclosure (2U) adapter (PCIe) Figure 4 |
2E0D | 02AN007 |
| P1-C3 P1-C4 P1-C5 P1-C6 |
I/O enclosure (2U) adapter (Fibre Channel host), SW 16 Gb
(4-port) Figure 5 |
HD4S | 02AM489 |
| P1-C3 P1-C4 P1-C5 P1-C6 |
I/O enclosure (2U) adapter (Fibre Channel host), LW-10 km 16 Gb
(4-port) Figure 5 |
HD4L | 02AM405 |
| P1-C9 | I/O enclosure (2U) adapter (PCN) Figure 6 |
2E0F | 02AN571 |
|
Notes:
|
|||
| Location | I/O enclosure part name | Part number |
|---|---|---|
| P1-C1-T1, T2, T3, T4 | Cable, serial attached SCSI (SAS); see: Storage enclosure part numbers, Models 98x, 8xE (SAS flash enclosure, 24 drive slots). | |
| P1-C1-T5, T6 | CEC enclosure PCIe cable; see CEC enclosure part numbers, Models 980, 983, 984. | |
| P1-C1-T7 | Not used | |
| P1-C3-Tx P1-C4-Tx P1-C5-Tx P1-C6-Tx x = 1, 2, 3, 4 |
Host cable, provided by customer | |
| P1-C2-T5, T6 | CEC enclosure PCIe cable; see CEC enclosure part numbers, Models 980, 983, 984. | |
| P1-C2-T7 | Not used | |
| P1-C7-T5, T6 | CEC enclosure PCIe cable; see CEC enclosure part numbers, Models 980, 983, 984. | |
| P1-C7-T7 | Not used | |
| P1-C8-T1, T2, T3, T4 | Cable, serial attached SCSI (SAS); see: Storage enclosure part numbers, Models 98x, 8xE (SAS flash enclosure, 24 drive slots). | |
| P1-C8-T5, T6 | CEC enclosure PCIe cable; see CEC enclosure part numbers, Models 980, 983, 984. | |
| P1-C8-T7 | Not used | |
| P1-C9-T1 | Power control network (PCN) cable | 02AN466 |
| P1-C9-T2 | Power control network (PCN) cable | 02AN467 |