I/O enclosure part numbers, Models 98x, 8xE (not 983)

The following lists information about I/O enclosure parts. Use Table 1 as a directory.

Note: The following part numbers are the most recent for this version of the Parts Catalog. Your storage facility or serviceable event FRU list might contain an older or newer part number. The parts-ordering system recognizes all valid part numbers and automatically substitutes an available part number as needed.
Table 1. Start here, I/O enclosure part numbers (Models 98x, 8xE)
I/O enclosure part name Figure
Backplane assembly Figure 1
Device adapter card Figure 2
Fan Figure 1
Fibre Channel host card Figure 2
Microbay Figure 3
PCIe and PCN card Figure 2
PCIe storage interface card Figure 2
Power supply Figure 1
All other parts (Find the appropriate figure below)
Figure 1. I/O enclosure locations (front) (models 98x, 8xE)
I/O enclosure locations (front) (models 98x)
Table 2. I/O enclosure FRUs, front of rack (Models 98x, 8xE)
Index I/O enclosure part name CCIN1 Part number
A1, A2 Fan   98Y6920
P1 Backplane assembly   98Y7074
E1, E2 Power supply   01AF592
Notes:
  1. Important, read this entire paragraph as there are exceptions to what part number to order. The custom card identification number (CCIN) identifies the physical features and logical behavior of a part. If two parts appear physically identical but have different CCINs, they are not interchangeable unless stated elsewhere in the maintenance package or by the next level of support. If two parts have different part numbers and yet have the same CCIN, they are interchangeable. When you order a part number that is reported in a serviceable event or call-home record, check whether the parts ordering system has a conditional substitute for DS8000® series. There are a couple of exceptions where the part number on the DS8000 FRU part number is not the same one that is reported and called home. The part number reported and called home might be the original Power Systems part number, which might have firmware that is not appropriate for the DS8000 series. You must order the DS8000 FRU part number to ensure that the correct firmware is present.
Note: In Figure 2, the 8-port Fibre Channel host card is shown; 4-port is similar.
Figure 2. I/O enclosure locations (rear) (models 98x, 8xE)
I/O enclosure locations (rear) (models 98x, 8xE)
Notes:
  • I/O enclosure PCIe storage interface card (locations C3 and C6) not shown.
  • The older generation I/O enclosure PCIe and PCN card might not include T3, T4, and T10 ports.
Table 3. I/O enclosure FRUs, rear of rack (Models 98x, 8xE)
Index (Figure 2) I/O enclosure part name CCIN1 Part number
2 (C1, C2, C4, C5) Fibre Channel Host Card, SW 8 Gb (4-port) HC4S 45W8086
2 (C1, C2, C4, C5) Fibre Channel Host Card, LW-10 km 8 Gb (4-port) HC4L 45W8093
2 (C1, C2, C4, C5) Fibre Channel Host Card, SW 8 Gb (8-port) HC8S 98Y3201
2 (C1, C2, C4, C5) Fibre Channel Host Card, LW-10 km 8 Gb (8-port) HC8L 98Y3202
2 (C1, C2, C4, C5) Fibre Channel Host Card, SW 16 Gb (4-port) HD4S 98Y6893
2 (C1, C2, C4, C5) Fibre Channel Host Card, LW-10 km 16 Gb (4-port) HD4L 98Y6892
2 (C1, C2, C4, C5) Fibre Channel host card, default CCIN2 HAFC See note 2
1 (C3, C6) Device adapter card, optical (4-port) DAD4 31P1452
3 (C3, C6) PCIe x8 storage interface card (Models 982, 98F only) (FRU kit includes PCIe storage interface card and storage enclosure PCIe cable)   98Y9231
4 (C3, C6) Device adapter card, SAS (flash) (Models 982, 98F, 988, 88E only) DAQN 01LT624
C7 PCIe and PCN card (without ports T3, T4, T10)
(Models 980, 98B, 981, 98E, 982, 98F only)
2DE1 (note 3) 98Y8281
C7 PCIe and PCN card (includes ports T3, T4, T10)
(All models 984, 84E, 985, 85E, 986, 86E, 988, 88E; some models 980, 98B, 981, 98E, 982, 98F)
2DEF (note 3) 01LL319
C7-T3, C7-T4 PCIe optical transceiver, MTP24   78P5105
C7-T3, C7-T4 Wrap plug for PCIe optical transceiver, MTP24   74Y0792
Notes:
  1. Important, read this entire paragraph as there are exceptions to what part number to order. The custom card identification number (CCIN) identifies the physical features and logical behavior of a part. If two parts appear physically identical but have different CCINs, they are not interchangeable unless stated elsewhere in the maintenance package or by the next level of support. If two parts have different part numbers and yet have the same CCIN, they are interchangeable.

    When you order a part number that is reported in a serviceable event or call-home record, check whether the parts ordering system has a conditional substitute for DS8000 series. There are a couple of exceptions where the part number on the DS8000 FRU part number is not the same one that is reported and called home. The part number reported and called home might be the original Power Systems part number, which might have firmware that is not appropriate for the DS8000 series. You must order the DS8000 FRU part number to ensure that the correct firmware is present.

  2. When a serviceable event is opened against a host card that has not yet been configured (for example, during an expansion rack or host card installation), the serviceable event displays the default CCIN and will not show a FRU part number. Use the table to select the part number that matches the card type being installed.
  3. Replace the PCIe and PCN card with the same card type that was removed.
Figure 3. Microbay tray locations
Microbay tray locations
Figure 4. Microbay cable tray
Microbay cable tray
Figure 5. Microbay location codes
Microbay location codes
Table 4. Microbay FRUs, rear of rack (Models 98x, 8xE)
Index (Figure 3) I/O enclosure part name CCIN Part number
C1, C2 Microbay DAMB 01LT162
Callout label 2 Figure 4 Microbay cable tray (not a FRU)   01LT194
Table 5. Microbay cable FRUs, rear of rack (Models 98x, 8xE)
Index (Figure 3, Figure 5) I/O enclosure part name Part number
(C1, C2) T1, T2, T3, T4 Cable, serial attached SCSI (SAS); see: Storage enclosure part numbers, Models 98x, 8xE (SAS flash enclosure, 24 drive slots).  
C1-T5, C2-T5 Not used  
C1-T6, C2-T6 (Figure 3, Figure 5)
E5x-J11, E5x-J12 (Figure 6, Figure 8)
Microbay power cable (from PJA E5x) (Models 984, 985, 986, 988, 8xE)
(FRU kit includes cable and label sheets)
98Y9794
C1-T6, C2-T6 (Figure 3, Figure 5)
C7-T10 (Figure 2)
Microbay power cable (from I/O enclosure) (Models 980, 98B, 981, 98E)
(FRU kit includes cable and label sheets)
01LL355
C1-T7, C2-T7 (Figure 3, Figure 5)
C7-T5, C7-T6 (Figure 2)
FRU kit, CXP-PCIe x8 signal cable (Models 984, 985, 986, 988, 8xE)
(FRU kit includes cable and label sheets)
98Y9790
Table 6. I/O enclosure cable FRUs, rear of rack (Models 98x, 8xE)
Index (Figure 2) I/O enclosure part name Part number
2 (C1, C2, C4, C5)
T0 - T3 or T0 - T7
Host cable, provided by customer  
1 (C3, C6) T1, T2, T3, T4 Cable, Fibre Channel (FC-AL), optical; see Storage enclosure part numbers, Models 98x, 8xE (FC/SAS, 12 drive slots) and Storage enclosure part numbers, Models 98x, 8xE (FC/SAS, 24 drive slots).  
3 (C3, C6) T1 Storage enclosure PCIe x8 cable (Models 982, 98F only); see Table 3. (FRU kit includes PCIe storage interface card and storage enclosure PCIe cable.)  
4 (C3, C6) T1, T2, T3, T4 Cable, serial attached SCSI (SAS), optical; see Storage enclosure part numbers, Models 98x, 8xE (SAS flash enclosure, 24 drive slots).  
C7-T1, C7-T2 CEC enclosure PCIe cable; see CEC enclosure part numbers for your model.  
C7-T3, C7-T4 PCIe optical transceiver, MTP24 78P5105
C7-T3, C7-T4 Wrap plug for PCIe optical transceiver, MTP24 74Y0792
C7-T3, C7-T4 Optical cable, MTP24, 40m 00LU284
C7-T3, C7-T4 Optical cable, MTP24, 150m 00LU287
C7-T5, C7-T6 FRU kit, CXP-PCIe x8 signal cable (Models 982, 98F only) 98Y8440
C7-T5, C7-T6 (Figure 2)
C1-T7, C2-T7 (Figure 3, Figure 5)
FRU kit, CXP-PCIe x8 signal cable (Models 984, 985, 986, 988, 8xE)
(FRU kit includes cable and label sheets)
98Y9790
C7-T10 (Figure 2)
C1-T6, C2-T6 (Figure 3, Figure 5)
Microbay power cable (from I/O enclosure) (Models 980, 98B, 981, 98E)
(FRU kit includes cable and label sheets)
01LL355
R1-XI3-C7-T10 (Figure 2) to E51-J10 and E42-J4
(Figure 6, Figure 7, Figure 8)

R1-XI4-C7-T10 (Figure 2) to E52-J10 and E41-J4
(Figure 6, Figure 7, Figure 8)
PJA input power "Y" cable (from I/O enclosure) (Models 984, 985, 986, 988) 98Y9793
C7-T10 (Figure 2) (except R1-XI3, R1-XI4)
E5x-J10 (Figure 6, Figure 8)
PJA input power cable (from I/O enclosure) (Model 984 all-flash; Models 985, 986, 988, 8xE) 98Y9792
Figure 6. Model 984, 985, 986, 988 base rack locations
Note: Rack-1 shown. PJAs E51, E52, E53, and E54 can also be present in Rack-2. DC-UPS locations are similar for models 98x and 8xE.
Model 984, 985, 986, 988 base rack locations
Figure 7. Power junction assembly (PJA) locations (models 984, 985, 986, 988)
Model 984, 985, 986, 988 power junction assembly (PJA) locations - E41 and E42
Figure 8. Direct power junction assembly (direct PJA) locations (models 984, 84E, 985, 85E, 986, 86E, 988, 88E)
Model 98x direct power junction assembly (direct PJA) locations - E51, E52, E53, and E54