MAP2100 PPS-1 (Top) with invalid PPS ID = 1 problem detected
A PPS-1 (Top) with invalid PPS ID = 1 problem was detected. This problem is typically caused by using the wrong sequence to connect PPS-1 (Top) cables during a repair action.
MAP2100 Section-1
Procedure
MAP2100 Section-2
Procedure
MAP2100 Section-3
Procedure
The upper PPS (location code E1) now needs to go through pseudo repair process to logically
reset and update the PPS ID. A pseudo repair means that you use the normal HMC FRU exchange guided
repair process, but do not disconnect or power off the FRU when directed.
Do one of the following:
- If the upper PPS (location code E1) is listed in the serviceable event FRU list, use the normal FRU exchange procedure. When the service Information Center exchange process is displayed, do not disconnect cables and switch off the power input CB00. Instead, return to the HMC screen and complete the FRU exchange process.
- If the upper PPS (location code E1) is not listed in the serviceable event FRU list, use MAP1230 Replace a FRU without using a serviceable event to replace the FRU. When the service Information Center exchange process is displayed, do not disconnect cables and switch off the power input CB00. Instead, return to the HMC screen and complete the FRU exchange process.

power input circuit breaker. See



cable.