MAP2150 Storage facility will not power on from zSeries host
When the zSeries remote power feature is installed, the first rack contains a ZLR type of Local / Remote switch card. The DIP switch located on each RPC card will have switch 3 set to the on (right) position. A failure that disables the remote power control can be internal or external to the storage facility. An interface wrap tool has been provided to enable the MAP to isolate the failure at ZLR local remote switch card.
Before you begin
- The feature is properly installed.
- zSeries feature switch is set to on (right) position on both RPC logic cards.
- All cable connections are correct.
- The ZLR local remote switch card switch is set to Remote.
- The management console is available and the power control mode at the management console is set to zSeries remote.
About this task
MAP2150 Section-1
Before you begin
Procedure
MAP2150 Section-2
Use this section to verify the remote power control interface.