FSPSPC1
If the system hangs after the code that sent you to this procedure displays in the control panel, perform these steps to reset the service processor.
About this task
Note: Storage complex repair actions must always be managed from the management console. To replace any FRUs identified in this
procedure, use . If the FRUs are listed in the serviceable
events, select them from there.
Procedure
Are you servicing a Model 941 with
more than one CEC enclosure connected
together with SMP cables (at the front of the system processor cards)?
- Yes. Verify that the CEC enclosure VPD card
is present in the first (top) drawer, and that a VPD card is not installed
in the second CEC enclosure.
If there are problems with the configuration of the VPD card, correct
them.
If the service processor goes to standby mode, this ends the procedure.
If the service processor still fails early in the boot process or the VPD card was configured correctly, continue to the next step.
- No. Continue to the next step. Select the procedure that applies
to the system on which you are working:
- Systems with a physical control panel. See Resetting the service processor on systems with a physical control panel.
- Systems with a logical control panel. See Resetting the service processor on systems with a logical control panel.