The failing component is one of the memory DIMMs.
Before you begin
Note: Storage complex repair actions must always be managed from the
management console. To replace any FRUs identified in this procedure, use . If the FRUs are listed in
this or another Serviceable Event, select them from there.
Procedure
- For Model 961, the possible
failing memory DIMMs are P1-Cx-Cy
x = 14-17 (CEC enclosure
memory card)
y = 1-4, 7-10 (CEC enclosure memory module)
This ends the procedure for Model 961.
- For Model 941 and Model 951, replace the FRUs in the order shown until
the problem is resolved.
Table 1. Replacing the failing
part
| Unit |
Failing part |
How to replace the failing part |
| CEC enclosure - Processor 1 |
DIMM 1 P2-C1-C1 DIMM 2 P2-C1-C2 DIMM
3 P2-C1-C3 DIMM 4 P2-C1-C4 DIMM 5 P2-C1-C5 DIMM
5 P2-C1-C5 DIMM 6 P2-C1-C6 DIMM 7 P2-C1-C7 DIMM
8 P2-C1-C8 DIMM 9 P2-C1-C9 DIMM
10 P2-C1-C10 DIMM 11 P2-C1-C11 DIMM 12 P2-C1-C12 |
Refer to Exchanging parts. |
| CEC enclosure - Processor 2 |
DIMM 1 P2-C2-C1 DIMM 2 P2-C2-C2
DIMM 3 P2-C2-C3 DIMM 4 P2-C2-C4 DIMM 5
P2-C2-C5 DIMM 6 P2-C2-C6 DIMM 7 P2-C2-C7 DIMM
8 P2-C2-C8 DIMM 9 P2-C1-C9 DIMM
10 P2-C1-C10 DIMM 11 P2-C1-C11 DIMM 12 P2-C1-C12 |
Refer to Exchanging parts. |
This ends the procedure for Model 941 and Model 951.