There has been a network adapter failure on this HMC.
About this task
Note: This SRC and symbolic FRU is not expected on DS8000® storage facility. Report this problem to the next level of support.
They might have you use the following procedure to isolate the problem.
Procedure
- Go to MAP7000 Entry point For storage facility private network problems and follow
the instructions to isolate the failure.
- Was a problem found?
- Is the peer management console with
the missing connection present in the topology?
- Yes, the problem was temporary and has resolved itself. This ends
the procedure.
- No, go to step 4.
- Is the management console that
reported the connection errors also reporting a hardware error with a network
adapter?
- Yes, service this network adapter error. This ends the procedure.
- No, go to step 5.
- Verify that the management console with
a missing connection is powered on and that its Ethernet connections are secure
and functioning. Does the problem persist?
- Yes, call your next level of support for assistance. This ends
the procedure.
- No. This ends the procedure.