BE6xxxxx
This section lists the BE6xxxxx system reference codes.
If the SRC listed in a serviceable event
is missing from the following table, ask your next level of support
for assistance.
Note: Next level, inform development of any SRCs not
defined in the table.
| System Reference Code | Description |
|---|---|
| BE610010 | Secure data overwrite process for customer data drives completed successfully. |
| BE610011 | Secure data overwrite process for customer data drives failed on customer data disks. |
| BE610012 | Secure data overwrite process for customer data drives failed to generate SDO completion certificate. |
| BE610013 | Secure data overwrite process for customer data drives failed when it detected that status is corrupted. |
| BE610014 | Secure data overwrite process for customer data drives failed to start monitoring process. |
| BE610015 | Secure data overwrite process for customer data drives failed when it detected an unexpected error. |
| BE610016 | Secure data overwrite process for customer data drives failed when a pre-check process detected an error. |
| BE610017 | Secure data overwrite process for customer data drives failed when it detected an incorrect storage facility state. |
| BE610018 | Secure data overwrite process for customer data drives failed when it detected customer logical configuration not fully removed. |
| BE610019 | Secure data overwrite process for customer data drives detected another process in progress. |
| BE61001A | Secure data overwrite process for customer data drives results available for offload. |
| BE61001B | Secure data overwrite process for customer data drives failed when it could not reset adapter configuration. |
| BE61001C | Secure data overwrite process for customer data drives failed with an unexpected microcode logic error. |
| BE61001D | Secure data overwrite process for customer data drives failed when it started on LPAR1 instead of LPAR0. Not a user error. |
| BE610020 | Secure data overwrite process completed successfully on CEC enclosure disk drives. |
| BE610021 | Secure data overwrite process failed on CEC enclosure disk drives. |
| BE610030 | Secure data overwrite process completed successfully on all managed storage facilities. |
| BE610031 | Secure data overwrite process failed on one or all managed storage facilities. |
| BE610034 | Secure data overwrite process stopped due to an unexpected reboot of the HMC in the middle of the overwrite process. |
| BE610035 | Secure data overwrite process failed when the HMC failed to generate SDO completion certificate(s). |
| BE610040 | Secure data overwrite process completed successfully on the secondary HMC. |
| BE610041 | Secure data overwrite process failed on the secondary HMC. |
| BE610042 | Secure data overwrite process did not complete on the secondary HMC. |
| BE610043 | Secure data overwrite process completed successfully on the primary HMC. |
| BE610044 | Secure data overwrite process failed on the primary HMC. |
| BE610050 | Secure data overwrite process failed when it timed out from HMC WUI interface. |
| BE610051 | Secure data overwrite process failed when RMC (HMC - LPAR) communication failed. |
| BE610060 | Secure data overwrite process SDO completion certificate offloaded successfully. |