Rack power and cooling location codes (Models 98x) (not 983)

Use Table 1 to find the part of the rack power and cooling system for which you seek location code information. For part numbers, see Rack power and cooling part numbers, Models 98x, 8xE.
Table 1. Rack power and cooling location codes
Part See
Overview of locations, base rack Figure 1
Figure 2
Battery service module set locations (front) Figure 5

Figure 7

Figure 8
DC-UPS locations (rear) Figure 3
Figure 4
DC-UPS locations (front) Figure 5
Figure 6
Direct power junction assembly (direct PJA) Figure 15
Ethernet switches Figure 1
Figure 2
Local remote switch card Figure 9
Power supplies, 12V Figure 1
Power junction assemblies (PJA) Figure 1
Figure 2
Figure 13
Figure 14
Power distribution unit (PDU) Figure 1
Figure 2
Figure 12
Rack identity card Figure 10
RPC card Figure 11

Overview of locations, base rack and expansion rack

Figure 1. Models 980, 981, 982 base rack locations
Note: Locations for models 980, 981, 982 are shown. DC-UPS locations are similar for models 98x and 8xE.
Model 980, 981, 982 base rack locations
Figure 2. Model 984, 985, 986, 988 base rack locations
Note: Rack-1 shown. PJAs E51, E52, E53, and E54 can also be present in Rack-2. DC-UPS locations are similar for models 98x and 8xE.
Model 984, 985, 986, 988 base rack locations
Table 2. Base rack locations, front and rear
Location code Part name
U2nnn.mmm.sssssss-E1 DC-UPS (left, facing rear)
U2nnn.mmm.sssssss-E1-Exx

(xx = 12)
Battery service module set
U2nnn.mmm.sssssss-E2 DC-UPS (right, facing rear)
U2nnn.mmm.sssssss-E2-Exx

(xx = 12)
Battery service module set
U2nnn.mmm.sssssss-Exx
(xx = 21 through 24)
Power distribution units
U2nnn.mmm.sssssss-Exx
(xx = 31 through 36)
(models 980, 981, 982)
12V Power supply
U2nnn.mmm.sssssss-Exx
(xx = 41, 42)
Power junction assembly (PJA)
U2nnn.mmm.sssssss-Exx
(xx = 51, 52)
(model 984)
Direct power junction assembly (PJA)
U2nnn.mmm.sssssss-Exx
(xx = 51 through 54)
(models 985, 986, 988)
Direct power junction assembly (PJA)
U2nnn.mmm.sssssss-SW1
Ethernet switch, black network
U2nnn.mmm.sssssss-SW2
Ethernet switch, gray network
Table 3. Location codes for an expansion rack
Location code Part name
U2nnn.mmm.sssssss-E1 DC-UPS (left, facing rear)
U2nnn.mmm.sssssss-E1-Exx
(xx = 12)
Battery service module set
U2nnn.mmm.sssssss-E2 DC-UPS (right, facing rear)
U2nnn.mmm.sssssss-E2-Exx
(xx = 12)
Battery service module set
U2nnn.mmm.sssssss-Exx
(xx = 21 through 24)
Power distribution units
U2nnn.mmm.sssssss-Exx
(xx = 51, 52)
(model 84E)
Direct power junction assembly (PJA)
U2nnn.mmm.sssssss-Exx
(xx = 51 through 54)
(models 85E, 86E, 88E)
Direct power junction assembly (PJA)

DC-UPS locations (rear)

Figure 3. Location codes for the DC-UPS (Models 98x and 8xE, single-phase power) (rear)
Location codes for the DC-UPS (Models 98x) (rear)
Figure 4. Location codes for the DC-UPS (Models 98x, three-phase power) (rear)
Location codes for the DC-UPS (three-phase Models 98x) (rear)
Table 4. DC-UPS locations (rear)
Location code Part name Connector
U2nnn.mmm.sssssss-Ex1, 2 DC-UPS (sheetmetal only enclosure, not a FRU)  
U2nnn.mmm.sssssss-Ex-A1 DC-UPS fan assembly  
U2nnn.mmm.sssssss-Ex-E1 DC supply unit  
U2nnn.mmm.sssssss-Ex-J1   PDU
U2nnn.mmm.sssssss-Ex-J2   PDU
U2nnn.mmm.sssssss-Ex-J3   DC-UPS
U2nnn.mmm.sssssss-Ex-J4   DC-UPS fan assembly
U2nnn.mmm.sssssss-Ex-J5   Jumper plug
U2nnn.mmm.sssssss-Ex-J6   DC-UPS, RPC card C1
U2nnn.mmm.sssssss-Ex-J7   DC-UPS, RPC card C2
U2nnn.mmm.sssssss-Ex-J8   Not used (Rack 1)
Rack Identity Card C5 (expansion rack)
U2nnn.mmm.sssssss-Ex-J9   DC-UPS
U2nnn.mmm.sssssss-Ex-J10   Input phase selection
U2nnn.mmm.sssssss-Ex-J11   Input phase selection
U2nnn.mmm.sssssss-Ex-J14   Mainline power
U2nnn.mmm.sssssss-Ex-P12   (Input phase selection cable)
U2nnn.mmm.sssssss-Ex-P13   (Input phase selection cable)
Notes:
  1. x = 1 is left (facing rear) DC-UPS; x = 2 is right (facing rear) DC-UPS.
  2. This is a sheetmetal-only enclosure that the DC-UPS module is contained in. It is not a FRU, but it is used during repairs to identify the DC-UPS.

Battery service module set locations, DC-UPS (front)

Figure 5. Battery service module (BSM) set locations (Models 98x single-phase power) (front)
Battery service module (BSM) set locations (Models 98x) (front)
Figure 6. Battery service module (BSM) set locations (Models 98x three-phase power) (front)
Battery service module (BSM) set locations (Models 98x, three-phase power) (front)
Figure 7. Battery service module, primary, locations (front)
Battery service module, primary, locations (front)
Figure 8. Battery service module, secondary, locations (front)
Battery service module, secondary, locations (front)
Table 5. Battery service module set locations (front)
Location code Part name Connector
U242n.mmm.sssssss-Ex-Eyy
  x = 1 (right DC-UPS, facing front)
  x = 2 (left DC-UPS, facing front)
  yy = 12 (single location in this DC-UPS)
 
Battery service module set
  • Primary module at upper right
  • Three secondary modules below and to left
 
U242n.mmm.sssssss-Ex-Eyy-E1 Battery service module, primary  
U242n.mmm.sssssss-Ex-Eyy-E1-J30   Battery service module set signal
U242n.mmm.sssssss-Ex-Eyy-E1-J20   Battery service module set power (208V)
U242n.mmm.sssssss-Ex-Eyy-E2
U242n.mmm.sssssss-Ex-Eyy-E3
U242n.mmm.sssssss-Ex-Eyy-E4
Battery service module, secondary  
U242n.mmm.sssssss-Ex-Eyy-E2-J31
U242n.mmm.sssssss-Ex-Eyy-E3-J31
U242n.mmm.sssssss-Ex-Eyy-E4-J31
  Battery service module set signal
U242n.mmm.sssssss-Ex-Eyy-E2-J21
U242n.mmm.sssssss-Ex-Eyy-E3-J21
U242n.mmm.sssssss-Ex-Eyy-E4-J21
  Battery service module set power (208V)

Local remote switch card locations

Figure 9. Location codes for the local remote switch card
Location codes for the local remote switch card
Table 6. Local remote switch card locations
Location code Part name Connector
U2nnn.mmm.sssssss-C6 Local remote switch card  
U2nnn.mmm.sssssss-C6-J5   RPC card C1
U2nnn.mmm.sssssss-C6-J6   RPC card C2

Rack identity card locations

Figure 10. Location codes for the rack identity card
Location codes for the rack identity card
Table 7. Rack identity card locations
Location code Part name Connector
U2nnn.mmm.sssssss-C5 Rack identity card  
U2nnn.mmm.sssssss-C5-J1   To RPC card C1 (Rack 1)
To DC-UPS E1 (expansion rack)
U2nnn.mmm.sssssss-C5-J2   To RPC card C2 (Rack 1)
To DC-UPS E2 (expansion rack)
U2nnn.mmm.sssssss-C5-J3   To rack operator panel LEDs
(front door of rack)

RPC card locations

Figure 11. Location codes for the RPC card (Model 98x)
Location codes for the RPC card (Model 98x)
Table 8. RPC card locations
Location code Part name Connector
U2nnn.mmm.sssssss-C1 RPC card (left, facing rear)  
U2nnn.mmm.sssssss-C2 RPC card (right, facing rear)  
U2nnn.mmm.sssssss-Cx-J1   Rack-ID card
U2nnn.mmm.sssssss-Cx-J4   Not used
U2nnn.mmm.sssssss-Cx-J201   DC-UPS Rack 1
U2nnn.mmm.sssssss-Cx-J202   Debug
U2nnn.mmm.sssssss-Cx-J203   DC-UPS Rack 2
U2nnn.mmm.sssssss-Cx-J204   Local/Remote card Rack 1
U2nnn.mmm.sssssss-Cx-J205   DC-UPS Rack 3
U2nnn.mmm.sssssss-Cx-J206   Not used
U2nnn.mmm.sssssss-Cx-J207   DC-UPS Rack 4
U2nnn.mmm.sssssss-Cx-J208   RPC to RPC
U2nnn.mmm.sssssss-Cx-J209   DC-UPS Rack 5
U2nnn.mmm.sssssss-Cx-J210   CEC FSP upper (I2C interface)
U2nnn.mmm.sssssss-Cx-J211   Not used
U2nnn.mmm.sssssss-Cx-J212   CEC LPAR upper (serial interface)
U2nnn.mmm.sssssss-Cx-J213   Not used
U2nnn.mmm.sssssss-Cx-J214   CEC FSP lower (I2C interface)
U2nnn.mmm.sssssss-Cx-J215   Not used
U2nnn.mmm.sssssss-Cx-J216   CEC LPAR lower (serial interface)
U2nnn.mmm.sssssss-Cx-J301   Power control network (PCN), Rack-1
U2nnn.mmm.sssssss-Cx-J302   Power control network (PCN), Rack-2
U2nnn.mmm.sssssss-Cx-J303   Not used
U2nnn.mmm.sssssss-Cx-J304   Not used
U2nnn.mmm.sssssss-Cx-J305   Not used
U2nnn.mmm.sssssss-Cx-J306   Not used

Power distribution units

Figure 12. Locations for power distribution unit (PDU) connectors
Locations for power distribution unit (PDU) connectors
Table 9. Power distribution unit locations
Location code Part name Connector
U2nnn.mmm.sssssss-E2x
(x = 1 through 4)
Power distribution unit  
U2nnn.mmm.sssssss-E2x-Jy
(y = 1 through 12)
  208VDC output to CEC enclosure, I/O enclosure, or storage enclosures
U2nnn.mmm.sssssss-E2x-Py
(y = 1, 2)
  208VDC input from DC-UPS (plug and cable are part of PDU)

Power junction assembly

Figure 13. Power junction assembly (PJA) locations (models 980, 981, 982)
Model 98x power junction assembly (PJA) locations
Figure 14. Power junction assembly (PJA) locations (models 984, 985, 986, 988)
Model 984, 985, 986, 988 power junction assembly (PJA) locations - E41 and E42
Figure 15. Direct power junction assembly (direct PJA) locations (models 984, 84E, 985, 85E, 986, 86E, 988, 88E)
Model 98x direct power junction assembly (direct PJA) locations - E51, E52, E53, and E54
Table 10. Power junction assembly (PJA) locations (models 980, 981, 982)
Location code Part name Connector
U2nnn.mmm.sssssss-E4x
(x = 1, 2)
Power junction assembly (PJA)  
U2nnn.mmm.sssssss-E4x-Jy
(y = 1, 2)
  Management console power
U2nnn.mmm.sssssss-E4x-J3
  n/a - J3 not present on this model
U2nnn.mmm.sssssss-E4x-Jy
(y = 4, 6, 8)
  12V input from power supply
U2nnn.mmm.sssssss-E4x-J5   12V output to Ethernet switch SW1
U2nnn.mmm.sssssss-E4x-J7   12V output to Ethernet switch SW2
U2nnn.mmm.sssssss-E4x-J9   12V output to management console display
Table 11. Power junction assembly (PJA) locations (models 984, 985, 986, 988)
Location code Part name Connector
U2nnn.mmm.sssssss-E4x
(x = 1, 2)
Power junction assembly (PJA)  
U2nnn.mmm.sssssss-E4x-Jy
(y = 1, 2)
  Management console power
UU2nnn.mmm.sssssss-E4x-Jy
(y = 3, 6, 8)
  N/A: J3, J6, J8 are not present on this model.
U2nnn.mmm.sssssss-E4x-J4   12V input from I/O enclosure
U2nnn.mmm.sssssss-E4x-J5   12V output to Ethernet switch SW1
U2nnn.mmm.sssssss-E4x-J7   12V output to Ethernet switch SW2
U2nnn.mmm.sssssss-E4x-J9   12V output to management console display
Table 12. Direct power junction assembly (direct PJA) locations (models 984, 84E)
Location code Part name Connector
U2nnn.mmm.sssssss-E5x
(x = 1, 2)
Power junction assembly (PJA)  
U2nnn.mmm.sssssss-E5x-J10   12V input from I/O enclosure
U2nnn.mmm.sssssss-E5x-J11   12V output to microbay
U2nnn.mmm.sssssss-E5x-J12   12V output to microbay (all-flash model 984 only)
Table 13. Direct power junction assembly (direct PJA) locations (models 985, 85E, 986, 86E)
Location code Part name Connector
U2nnn.mmm.sssssss-E5x
(x = 1 through 4)
Power junction assembly (PJA)  
U2nnn.mmm.sssssss-E5x-J10   12V input from I/O enclosure
U2nnn.mmm.sssssss-E5x-J11   12V output to microbay
U2nnn.mmm.sssssss-E5x-J12   Not used
Table 14. Direct power junction assembly (direct PJA) locations (models 988, 88E)
Location code Part name Connector
U2nnn.mmm.sssssss-E5x
(x = 1 through 4)
Power junction assembly (PJA  
U2nnn.mmm.sssssss-E5x-J10   12V input from I/O enclosure
U2nnn.mmm.sssssss-E5x-J11   12V output to microbay
U2nnn.mmm.sssssss-E5x-J12   12V output to microbay