Exchange the I/O enclosure power supply
Before you begin
Use approved ESD procedures to prevent damage.
Attention:
- This procedure is not a stand-alone procedure. Customer disruption and damage to the hardware might occur when microcode and power boundaries are not in the proper conditions for this service action.
- If a serviceable event FRU repair directed you to this procedure, the microcode and power boundaries are already set.
- If a serviceable event FRU repair did not direct you to this procedure, see MAP1230 Replace a FRU without using a serviceable event.
Notes:
- All the cables and FRUs to be removed must be uniquely identified so they can be reinstalled correctly.
- If an installed earthquake resistance kit prevents you from accessing this FRU, refer to MAP1600.
Remove the I/O enclosure power supply
About this task
Attention: Power supplies are hot-pluggable FRUs.
Remove only one power supply at a time.
on the I/O enclosure power supply must be
lit before you go to the next step. This ensures that the I/O enclosure
remains powered on when the failing power supply is removed. If the
power good LED is not lit, DO NOT CONTINUE. Instead,
input power to power supply
identify for I/O enclosure power supply