MAP1245 Finding FRUs by using location codes
How to convert a location code to the storage facility location that contains the FRU or function.
In most cases, any FRU listed in a serviceable event includes a location code. Cables are a special case because they do not have their own location code. Cables that can be identified as failing by the microcode use the location of the FRU connectors they connect to. This means that those cables have two location codes, one for each end of the cable. For a Y cable in the power system, there will be three location codes. Cables that are not reported directly by the microcode are determined by guided isolation procedures.
MAP1245 Section-1
- Location codes have two parts:
- The "MTMS" (machine type, model, serial number) of the rack or enclosure within the rack
- The physical location within the rack or enclosure
Example of location code: 2107.D02.1300177-P1-C2-T3- The
MTMS
(machine type, model, serial number):- 2107.D02 = storage enclosure (machine type/model)
- 1300177 = storage enclosure serial number (visible on the bar code label)
- The physical location:
- P1- = Planar 1
- C2- = FCIC card 2 (right FCIC in storage enclosure)
- T3 = FC-AL cable connector (third FC-AL cable connector from left on FCIC card)
- To convert the MTMS or location code to the FRU type or enclosure type, select the following conditions that apply:
| MTMS or location code | Description | MTMS label location |
|---|---|---|
| 533n.983.ssssss0 | Storage Facility | On the front of the management enclosure. (The SF is not a physical FRU; it is a managed entity that contains components in one or more racks). |
| 2107.983.ssssss1 | Storage Facility Image (SFI) | (The SFI is not a physical FRU; it is a logical partition on the CEC enclosure). |
| 533n.AB8.ssssss0 (Model 983) | Storage Facility Rack (base, DS8882) | Not on label (obtained by substituting AB8 for 983 in Storage Facility MTMS). |
| U533n.mmm.sssssss-Cx (x=1, 2) |
Rack Power Control (RPC) card | On the front of the management enclosure. |
| U533n.mmm.sssssss-Cx (x=6) |
Local/Remote switch card | On the front of the management enclosure. |
| U533n.mmm.sssssss-E6x (x=1, 2) |
Uninterruptible power supply (UPS) | On the front of the management enclosure. |
| U533n.mmm.sssssss-E6x-C1 (x=1, 2) |
UPS network card | On the front of the management enclosure. |
| U533n.nnn.mmm.sssssss-E6y-Ex (y=1,2; x=1) |
UPS battery | On the front of the management enclosure. |
| U2107.D04.sssssss | Storage enclosure (24 drive slots) |
|
| 8284-22A*sssssss (Model 983) | Server model (also called "system" or "CEC complex") |
|
| U78CB.001.sssssss (Model 983) | CEC enclosure feature code model (also called enclosure type model) |
Upper surface of CEC enclosure (hidden by front cover). |
| U1600.iGn.sssssss | I/O enclosure (2U) | On the front of the I/O enclosure, right side wall. |
| 8100.LI7.sssssss | Model 98x management console | On the front of the management console. |
| MTMS or location code | Description | MTMS label location | Second part of Location Code |
|---|---|---|---|
| 283n.980.ssssss0 283n.981.ssssss0 283n.982.ssssss0 283n.984.ssssss0 283n.985.ssssss0 283n.986.ssssss0 283n.988.ssssss0 |
Storage Facility | On the rack 1 front door, just above the latch handle. (The SF is not a physical FRU, it is a managed entity that contains one or more racks). |
|
| 2107.980.ssssss1 2107.981.ssssss1 2107.982.ssssss1 2107.984.ssssss1 2107.985.ssssss1 2107.986.ssssss1 2107.988.ssssss1 |
Storage Facility Image (SFI) | (The SFI is not a physical FRU; it is a logical partition on the CEC enclosure.) | |
| 283n.AB4.ssssss0 (Model 980) | Storage Facility Rack (base, DS8884) | Not on label (obtained by substituting AB4 for 980 in Storage Facility MTMS). | Rack power and cooling location codes (Models 98x) (not 983) |
| 283n.AB7.ssssss0 (Model 984) | Storage Facility Rack (base, DS8884, single-phase) | Not on label (obtained by substituting AB7 for 984 in Storage Facility MTMS). | Rack power and cooling location codes (Models 98x) (not 983) |
| 283n.AE4.ssssss0 (Model 981) | Storage Facility Rack (base, DS8886, single-phase) | Not on label (obtained by substituting AE4 for 981 in Storage Facility MTMS). | Rack power and cooling location codes (Models 98x) (not 983) |
| 283n.AE5.ssssss0 (Model 981) | Storage Facility Rack (base, DS8886, three-phase) | Not on label (obtained by substituting AE5 for 981 in Storage Facility MTMS). | Rack power and cooling location codes (Models 98x) (not 983) |
| 283n.AE6.ssssss0 (Model 985) | Storage Facility Rack (base, DS8886, single-phase) | Not on label (obtained by substituting AE6 for 985 in Storage Facility MTMS). | Rack power and cooling location codes (Models 98x) (not 983) |
| 283n.AE7.ssssss0 (Model 986) | Storage Facility Rack (base, DS8886, three-phase) | Not on label (obtained by substituting AE7 for 986 in Storage Facility MTMS). | Rack power and cooling location codes (Models 98x) (not 983) |
| 283n.AF4.ssssss0 (Model 982) | Storage Facility Rack (base, DS8888) | Not on label (obtained by substituting AF4 for 982 in Storage Facility MTMS). | Rack power and cooling location codes (Models 98x) (not 983) |
| 283n.AF9.ssssss0 (Model 988) | Storage Facility Rack (base, DS8888) | Not on label (obtained by substituting AF9 for 988 in Storage Facility MTMS). | Rack power and cooling location codes (Models 98x) (not 983) |
| 283n.989.ssssss0 (Model 98B) | Storage Facility Rack (expansion, DS8884) (Rack-2, with I/O enclosures) | Not on label - obtained by substituting 989 for 98B in expansion rack MTMS, which is on the rack front door, just above the latch handle. | Rack power and cooling location codes (Models 98x) (not 983) |
| 283n.98A.ssssss0 (Model 98B) | Storage Facility Rack (expansion, DS8884) (Rack-3, without I/O enclosures) | Not on label - obtained by substituting 98A for 98B in expansion rack MTMS, which is on the rack front door, just above the latch handle. | Rack power and cooling location codes (Models 98x) (not 983) |
| 283n.98E.ssssss0 (Model 98E) | Storage Facility Rack (expansion, DS8886, single-phase) (Rack-2, with I/O enclosures) | On the rack front door, just above the latch handle. | Rack power and cooling location codes (Models 98x) (not 983) |
| 283n.98F.ssssss0 (Model 98E) | Storage Facility Rack (expansion, DS8886, single-phase) (without I/O enclosures) | Not on label - obtained by substituting 98F for 98E in expansion rack MTMS, which is on the rack front door, just above the latch handle. | Rack power and cooling location codes (Models 98x) (not 983) |
| 283n.A8E.ssssss0 (Model 98E) | Storage Facility Rack (expansion, DS8886, three-phase) (Rack-2, with I/O enclosures) | Not on label - obtained by substituting A8E for 98E in expansion rack MTMS, which is on the rack front door, just above the latch handle. | Rack power and cooling location codes (Models 98x) (not 983) |
| 283n.A8F.ssssss0 (Model 98E) | Storage Facility Rack (expansion, DS8886, three-phase) (without I/O enclosures) | Not on label - obtained by substituting A8F for 98E in expansion rack MTMS, which is on the rack front door, just above the latch handle. | Rack power and cooling location codes (Models 98x) (not 983) |
| 283n.98D.ssssss0 (Model 98F) | Storage Facility Rack (expansion, DS8888) (Rack-2, with I/O enclosures) | Not on label - obtained by substituting 98D for 98F in expansion rack MTMS, which is on the rack front door, just above the latch handle. | Rack power and cooling location codes (Models 98x) (not 983) |
| 283n.884.ssssss0 (Model 84E) | Storage Facility Rack (expansion, DS8884, single-phase) (Rack-2, with I/O enclosures) | Not on label - obtained by substituting 884 for 84E in expansion rack MTMS, which is on the rack front door, just above the latch handle. | Rack power and cooling location codes (Models 98x) (not 983) |
| 283n.885.ssssss0 (Model 84E) | Storage Facility Rack (expansion, DS8884, single-phase) (without I/O enclosures) | Not on label - obtained by substituting 885 for 84E in expansion rack MTMS, which is on the rack front door, just above the latch handle. | Rack power and cooling location codes (Models 98x) (not 983) |
| 283n.886.ssssss0 (Model 85E) | Storage Facility Rack (expansion, DS8886, single-phase) (Rack-2, with I/O enclosures) | Not on label - obtained by substituting 886 for 85E in expansion rack MTMS, which is on the rack front door, just above the latch handle. | Rack power and cooling location codes (Models 98x) (not 983) |
| 283n.887.ssssss0 (Model 85E) | Storage Facility Rack (expansion, DS8886, single-phase) (without I/O enclosures) | Not on label - obtained by substituting 887 for 85E in expansion rack MTMS, which is on the rack front door, just above the latch handle. | Rack power and cooling location codes (Models 98x) (not 983) |
| 283n.A86.ssssss0 (Model 86E) | Storage Facility Rack (expansion, DS8886, three-phase) (Rack-2, with I/O enclosures) | Not on label - obtained by substituting A86 for 86E in expansion rack MTMS, which is on the rack front door, just above the latch handle. | Rack power and cooling location codes (Models 98x) (not 983) |
| 283n.A87.ssssss0 (Model 86E) | Storage Facility Rack (expansion, DS8886, three-phase) (without I/O enclosures) | Not on label - obtained by substituting A87 for 86E in expansion rack MTMS, which is on the rack front door, just above the latch handle. | Rack power and cooling location codes (Models 98x) (not 983) |
| 283n.A8C.ssssss0 (Model 88E) | Storage Facility Rack (expansion, DS8888, three-phase) (without I/O enclosures) | Not on label - obtained by substituting A8C for 88E in expansion rack MTMS, which is on the rack front door, just above the latch handle. | Rack power and cooling location codes (Models 98x) (not 983) |
| 283n.A8D.ssssss0 (Model 88E) | Storage Facility Rack (expansion, DS8888, three-phase) (Rack-2, with I/O enclosures) | Not on label - obtained by substituting A8D for 88E in expansion rack MTMS, which is on the rack front door, just above the latch handle. | Rack power and cooling location codes (Models 98x) (not 983) |
|
U283n.mmm.sssssss-Cx
(x=1, 2) |
Rack Power Control (RPC) card | On the rack front door, just above the latch handle. | Rack power and cooling location codes (Models 98x) (not 983) |
|
U283n.mmm.sssssss-Cx
(x=5) |
Rack identity card | On the rack front door, just above the latch handle. | Rack power and cooling location codes (Models 98x) (not 983) |
|
U283n.mmm.sssssss-Cx
(x=6) |
Local/Remote switch card | On the rack front door, just above the latch handle. | Rack power and cooling location codes (Models 98x) (not 983) |
|
U283n.mmm.sssssss-Ex
(x=1, 2) |
DC uninterruptible power supply (DC-UPS) | On the rack front door, just above the latch handle. | Rack power and cooling location codes (Models 98x) (not 983) |
|
U2nnn.mmm.sssssss-Ey-Exx
(y=1,2 xx=12) |
DC-UPS battery service module (BSM set) | On the rack front door, just above the latch handle. | Rack power and cooling location codes (Models 98x) (not 983) |
|
U283n.mmm.sssssss-E2x
(x=1,2, 3, 4) |
Power distribution unit (PDU) | On the rack front door, just above the latch handle. | Rack power and cooling location codes (Models 98x) (not 983) |
|
U283n.mmm.sssssss-E3x
(x=1,2, 3, 4, 5, 6) |
Power supply (12V) | On the rack front door, just above the latch handle. | Rack power and cooling location codes (Models 98x) (not 983) |
|
U283n.mmm.sssssss-E4x
(x=1, 2) |
Power junction assembly (PJA) | On the rack front door, just above the latch handle. | Rack power and cooling location codes (Models 98x) (not 983) |
| U283n.mmm.sssssss-E5x (x=1, 2, 3, 4) |
Direct power junction assembly (direct PJA) | On the rack front door, just above the latch handle. | Rack power and cooling location codes (Models 98x) (not 983) |
| U2107.D02.sssssss (Model 98x) | Storage enclosure (12 and 24 DDM slots) |
|
Storage enclosure location codes (Models 98x, FC/SAS, 12 and 24 drive slots) |
| U2107.D03.sssssss (Model 98x) | Storage enclosure (30 SSD slots) (High-performance flash enclosure) |
|
Storage enclosure location codes (Models 98x, PCIe flash enclosure, 30 SSD slots, 1.8 inches) |
| U2107.D04.sssssss (Model 98x) | Storage enclosure (24 drive slots) (High-performance flash enclosure, Gen2) |
|
Storage enclosure location codes (Models 98x, SAS flash enclosure, 24 drive slots, 2.5 inches) |
| 8284-22A*sssssss (Models 980,
984) 8286-42A*sssssss (Models 981, 985, 986) 8408-E8E*sssssss (Models 982, 988) 8408-44E*sssssss (Model 988) |
Server model (also called systemor CEC complex) |
|
CEC enclosure location codes (Models 980, 983, 984) CEC enclosure location codes (Models 981, 985, 986) CEC enclosure location codes (Models 982, 988) |
| U78CB.001.sssssss (Models 980,
984) U78C9.001.sssssss (Models 981, 985, 986) U78C7.001.sssssss (Models 982, 988) |
CEC enclosure feature code.model (also called enclosure type.model) |
Upper surface of CEC enclosure (hidden by front cover). | CEC enclosure location codes (Models 980, 983, 984) CEC enclosure location codes (Models 981, 985, 986) CEC enclosure location codes (Models 982, 988) |
| U1500.rBn.sssssss | I/O enclosure | On the front of the I/O enclosure, right side wall, next to the right I/O enclosure power supply. | I/O enclosure location codes (Models 98x) (not 983) |
| 8100.LI7.sssssss | Model 98x management console | On the front of the management console. |
| MTMS or location code | Description | MTMS label location | Second part of Location Code |
|---|---|---|---|
| 242n.961.ssssss0 | Storage Facility | On the rack 1 front door, just above the latch handle. Also on rack UEPO panel
(behind front door), above UEPO switch. (The SF is not a physical FRU, it is a managed entity that contains one or more racks). |
|
| 2107.961.ssssss1 | Storage Facility Image (SFI) | (The SFI is not a physical FRU; it is a logical partition on the CEC enclosure.) | |
| 242n.AB2.ssssss0 (Model 961) | Storage Facility Rack (base, business class) | Not on label (obtained by substituting AB2 for 961 in Storage Facility MTMS). | Rack power and cooling location codes (Models 961, 96E) |
| 242n.AE2.ssssss0 (Model 961) | Storage Facility Rack (base) | Not on label (obtained by substituting AE2 for 961 in Storage Facility MTMS). | Rack power and cooling location codes (Models 961, 96E) |
| 242n.AF2.ssssss0 (Model 961) | Storage Facility Rack (base) | Not on label (obtained by substituting AF2 for 961 in Storage Facility MTMS). | Rack power and cooling location codes (Models 961, 96E) |
| 242n.96B.ssssss0 (Model 96E) | Storage Facility Rack (expansion, business class) (Rack-2, with I/O enclosures) | Not on label - obtained by substituting 96B for 96E in expansion rack MTMS, which is on the rack front door, just above the latch handle. Also on rack UEPO panel (behind front door), above UEPO switch. | Rack power and cooling location codes (Models 961, 96E) |
| 242n.96C.ssssss0 (Model 96E) | Storage Facility Rack (expansion, business class) (Rack-3, without I/O enclosures) | Not on label - obtained by substituting 96C for 96E in expansion rack MTMS, which is on the rack front door, just above the latch handle. Also on rack UEPO panel (behind front door), above UEPO switch. | Rack power and cooling location codes (Models 961, 96E) |
| 242n.96D.ssssss0 (Model 96E) | Storage Facility Rack (expansion, business class) (Rack-4, without I/O enclosures) | Not on label - obtained by substituting 96D for 96E in expansion rack MTMS, which is on the rack front door, just above the latch handle. Also on rack UEPO panel (behind front door), above UEPO switch. | Rack power and cooling location codes (Models 961, 96E) |
| 242n.96E.ssssss0 (Model 96E) | Storage Facility Rack (expansion) (Rack-2, with I/O enclosures) |
On the rack front door, just above the latch handle. Also on rack UEPO panel (behind front door), above UEPO switch. | Rack power and cooling location codes (Models 961, 96E) |
| 242n.96F.ssssss0 (Model 96E) | Storage Facility Rack (expansion) (without I/O enclosures) |
Not on label - obtained by substituting 96F for 96E in expansion rack MTMS, which is on the rack front door, just above the latch handle. Also on rack UEPO panel (behind front door), above UEPO switch. | Rack power and cooling location codes (Models 961, 96E) |
|
U242n.mmm.sssssss-Ax
(x=1, 2, 3, 4) |
Ethernet switch tray fan | On the rack front door, just above the latch handle. | Rack power and cooling location codes (Models 961, 96E) |
|
U242n.mmm.sssssss-Cx
(x=1, 2) |
Rack Power Control (RPC) card | On the rack front door, just above the latch handle. | Rack power and cooling location codes (Models 961, 96E) |
|
U242n.mmm.sssssss-Cx
(x=5) |
Rack identity card | On the rack front door, just above the latch handle. | Rack power and cooling location codes (Models 961, 96E) |
|
U242n.mmm.sssssss-Cx
(x=6) |
Local/Remote or zSeries switch card | On the rack front door, just above the latch handle. | Rack power and cooling location codes (Models 961, 96E) |
|
U242n.mmm.sssssss-Ex
(x=1, 2) |
DC uninterruptible power supply (DC-UPS) | On the rack front door, just above the latch handle. | Rack power and cooling location codes (Models 961, 96E) |
|
U2nnn.mmm.sssssss-Ey-Exx
(y=1,2 xx=10, 11,12) |
DC-UPS battery service module (BSM set) | On the rack front door, just above the latch handle. | Rack power and cooling location codes (Models 961, 96E) |
|
U242n.mmm.sssssss-E2x
(x=1,2, 3, 4, 5, 6) |
Power distribution unit (PDU) | On the rack front door, just above the latch handle. | Rack power and cooling location codes (Models 961, 96E) |
|
U242n.mmm.sssssss-E3x
(x=1,2, 3, 4, 5, 6) |
Power supply (12V, 20V) | On the rack front door, just above the latch handle. | Rack power and cooling location codes (Models 961, 96E) |
|
U242n.mmm.sssssss-E4x
(x=1, 2) |
Power junction assembly (PJA) | On the rack front door, just above the latch handle. | Rack power and cooling location codes (Models 961, 96E) |
| U2107.D02.sssssss (Model 961) | Storage enclosure (12 and 24 DDM slots) |
|
Storage enclosure location codes (Models 961, 96E, FC/SAS, 12 and 24 drive slots) |
| U2107.D03.sssssss (Model 961) | Storage enclosure (30 SSD slots) |
|
Storage enclosure location codes (Models 961, 96E, PCIe flash enclosure, 30 SSD slots, 1.8 inches) |
| 8205-E6C*sssssss 8205-E6D*sssssss |
Server model (also called systemor CEC complex) |
|
CEC enclosure location codes (Model 961) |
| U78AA.001.sssssss | CEC enclosure feature code.model (also called enclosure type.model) |
Right side of CEC enclosure, to the right of the disk drive enclosure (hidden by front cover). | CEC enclosure location codes (Model 961) |
| U1400.rBn.sssssss | I/O enclosure | On the front of the I/O enclosure, at the bottom of the left I/O enclosure power supply. | I/O enclosure location codes (Models 961, 96E) |
| 4061.mmm.sssssss | ThinkPad W500 laptop management console | On the bottom of the ThinkPad laptop. | Management console (MC) server location codes (Models 961, 951, 941) |
| 4349.mmm.sssssss | ThinkPad T510 laptop management console | On the bottom of the ThinkPad laptop. | Management console (MC) server location codes (Models 961, 951, 941) |
| 4242.mmm.sssssss | ThinkPad T520 laptop management console | On the bottom of the ThinkPad laptop. | Management console (MC) server location codes (Models 961, 951, 941) |
| 2394.mmm.sssssss | ThinkPad T530 laptop management console | On the bottom of the ThinkPad laptop. | Management console (MC) server location codes (Models 961, 951, 941) |
| 0BFS.mmm.sssssss | ThinkPad T540 laptop management console | On the bottom of the ThinkPad laptop. Label shows machine type and model 20BF-S0UDxx (10 digits), with an 8-digit serial number. Location code contains a 4-digit machine type (0BFS) 3-digit model (OUD), 7-digit serial. |
Management console (MC) server location codes (Models 961, 951, 941) |
| MTMS or location code | Description | MTMS label location | Second part of Location Code |
|---|---|---|---|
| 242n.951.ssssss0 | Storage Facility | On the rack 1 front door, just above the latch handle. Also on rack UEPO panel
(behind front door), to left of UEPO switch. (The SF is not a physical FRU, it is a managed entity that contains one or more racks). |
|
|
2107.951.ssssss1
|
Storage Facility Image (SFI) | (The SFI is not a physical FRU; it is a logical partition on the CEC enclosure.) | |
| 242n.AE1.ssssss0 (Model 951) | Storage Facility Rack (base) | Not on label (obtained by substituting AE1 for 951 in Storage Facility MTMS). | Rack power and cooling location codes (Models 951, 95E) |
| 242n.AB1.ssssss0 (Model 951) | Storage Facility Rack (base) (business class cabling) |
Not on label (obtained by substituting AB1 for 951 in Storage Facility MTMS). | Rack power and cooling location codes (Models 951, 95E) |
| 242n.95E.ssssss0 (Model 95E) | Storage Facility Rack (expansion) (Rack-2, with I/O enclosures) |
On the rack front door, just above the latch handle. Also on rack UEPO panel (behind front door), to left of UEPO switch. | Rack power and cooling location codes (Models 951, 95E) |
| 242n.95F.ssssss0 (Model 95E) | Storage Facility Rack (expansion) (without I/O enclosures) |
Not on label - obtained by substituting 95F for 95E in expansion rack MTMS, which is on the rack front door, just above the latch handle. Also on rack UEPO panel (behind front door), to left of UEPO switch. | Rack power and cooling location codes (Models 951, 95E) |
U242n-mmm.sssssss-Ax
)(x=1, 2, 3, 4) |
Ethernet switch tray fan | On the rack front door, just above the latch handle. | Rack power and cooling location codes (Models 951, 95E) |
|
U242n-mmm.sssssss-Cx
(x=1, 2) |
Rack Power Control (RPC) card | On the rack front door, just above the latch handle. | Rack power and cooling location codes (Models 951, 95E) |
|
U242n.mmm.sssssss-Cx
(x=5) |
Rack identity card | On the rack front door, just above the latch handle. | Rack power and cooling location codes (Models 951, 95E) |
|
U242n.mmm.sssssssCx
(x=6) |
Local/Remote or zSeries switch card | On the rack front door, just above the latch handle. | Rack power and cooling location codes (Models 951, 95E) |
|
U242n.mmm.sssssss-Ex
(x=1, 2) |
Primary Power Supply (PPS) | On the rack front door, just above the latch handle. | Rack power and cooling location codes (Models 951, 95E) |
|
U242n.mmm.sssssss-Ex
(x=10, 11, 12) |
Battery module enclosure | On the rack front door, just above the latch handle. | Rack power and cooling location codes (Models 951, 95E) |
|
U242n.mmm.sssssss-E2x
(x=1, 2, 3, 4, 5, 6) |
Power distribution unit (PDU) | On the rack front door, just above the latch handle. | Rack power and cooling location codes (Models 951, 95E) |
| U2107.D02.sssssss (Model 951) | Storage enclosure |
|
Storage enclosure location codes (Models 951, 95E) |
| 9117-MMA*sssssss | Server model (also called systemor CEC complex) (CEC complex is 1 or more than 1 CEC enclosure cabled together and controlled by the service processor in the first CEC enclosure) |
On the front of the CEC enclosure, on the operator panel. | CEC enclosure location codes (Models 941, 951) |
| U789D.001.sssssss | CEC enclosure feature
code.model (also called enclosure type.model) (a CEC complex might have more than one CEC enclosure, each with a unique ssssss) |
On the front of the CEC enclosure, at the far right, in between the rack mounting screws (in a vertical orientation). | CEC enclosure location codes (Models 941, 951) |
| U1400.rBn.sssssss | I/O enclosure | On the front of the I/O enclosure, at the bottom of the left I/O enclosure power supply. | I/O enclosure location codes (Models 951, 95E) |
| 8676.mmm.sssssss | x335 management console | On the front of the HMC server, at the far right, near the thumb screw (in a vertical orientation). | Management console (MC) server location codes (Models 961, 951, 941) |
| 8837.mmm.sssssss | x3550 management console | On the front of the HMC server, at the far right, near the thumb screw (in a vertical orientation). | Management console (MC) server location codes (Models 961, 951, 941) |
| 7978.mmm.sssssss | x336 management console | On the front of the HMC server, at the far right, near the thumb screw (in a vertical orientation). | Management console (MC) server location codes (Models 961, 951, 941) |
| 4061.mmm.sssssss | ThinkPad W500 laptop management console | On the bottom of the ThinkPad laptop. | Management console (MC) server location codes (Models 961, 951, 941) |
| 4349.mmm.sssssss | ThinkPad T510 laptop management console | On the bottom of the ThinkPad laptop. | Management console (MC) server location codes (Models 961, 951, 941) |
| 4242.mmm.sssssss | ThinkPad T520 laptop management console | On the bottom of the ThinkPad laptop. | Management console (MC) server location codes (Models 961, 951, 941) |
| MTMS or location code | Description | MTMS label location | Second part of Location Code |
|---|---|---|---|
| 242n.941.ssssss0 | Storage Facility | On the Rack-1 front or rear door, just above the latch handle. Also, on Rack-1
UEPO panel (behind front door), above power and attention LEDs. (The SF is not a physical FRU; it is Rack-1 and any attached expansion racks.) |
|
|
2107.941.ssssssy
(y=1, 2) |
Storage Facility Image (SFI) | (The SFI is not a physical FRU; it is a logical partition on the CEC enclosure.) | |
| 242n.A01.ssssss0 | Storage Facility Rack (base) | Not on label (obtained by substituting A01 for 941 in Storage Facility MTMS). | Rack power and cooling location codes (Models 941, 94E) |
|
242n.94E.ssssss0
2nnn.92E.ssssss0 |
Storage Facility Rack (expansion) | On the rack front or rear door, just above the latch handle. Also on rack UEPO panel (behind front door), above power and attention LEDs. Model 92E only: On the rack operator panel below the UEPO red switch cover. |
Rack power and cooling location codes (Models 941, 94E) |
|
U242n.mmm.sssssss-Ax
(x=1, 2, 3) |
DASD Fan Trays | On the rack front or rear door, just above the latch handle. | Rack power and cooling location codes (Models 941, 94E) |
|
U242n.mmm.sssssss-Cx
(x=1, 2) |
Rack Power Control (RPC) card | On the rack front or rear door, just above the latch handle. | Rack power and cooling location codes (Models 941, 94E) |
|
U242n.mmm.sssssss-Cx
(x=3, 4) |
Fan sense card | On the rack front or rear door, just above the latch handle. | Rack power and cooling location codes (Models 941, 94E) |
|
U242n.mmm.sssssss-Cx
(x=5) |
Rack identity card | On the rack front or rear door, just above the latch handle. | Rack power and cooling location codes (Models 941, 94E) |
|
U242n.mmm.sssssss-Cx
(x=6) |
Local/Remote or zSeries switch card | On the rack front or rear door, just above the latch handle. | Rack power and cooling location codes (Models 941, 94E) |
|
U242n.mmm.sssssss-Ex
(x=1, 2) |
Primary Power Supply (PPS) | On the rack front or rear door, just above the latch handle. | Rack power and cooling location codes (Models 941, 94E) |
|
U242n.mmm.sssssss-Ex
(x=10, 11, 12) |
Battery module enclosure | On the rack front or rear door, just above the latch handle. | Rack power and cooling location codes (Models 941, 94E) |
| U2107.D01.sssssss | Storage enclosure | On the front of the storage enclosure, at the far right in between the rack mounting screws. | Storage enclosure location codes (Models 941, 94E) |
| 9117-MMA*sssssss | Server model (also called systemor CEC complex) (CEC complex is 1 or more than 1 CEC enclosure cabled together and controlled by the service processor in the first CEC enclosure) |
On the front of the CEC enclosure, on the operator panel. | CEC enclosure location codes (Models 941, 951) |
| U789D.001.sssssss | CEC enclosure feature
code.model (also called enclosure type.model) (a CEC complex might have more than one CEC enclosure, each with a unique ssssss) |
On the front of the CEC enclosure, at the far right, in between the rack mounting screws (in a vertical orientation). | CEC enclosure location codes (Models 941, 951) |
| U1400.rBn.sssssss | I/O enclosure | On the front of the I/O enclosure, at the bottom of the left I/O enclosure power supply. | I/O enclosure location codes (Models 941, 94E) |
| 8676.mmm.sssssss | x335 management console | On the front of the HMC server, at the far right, near the thumb screw (in a vertical orientation). | Management console (MC) server location codes (Models 961, 951, 941) |
| 8837.mmm.sssssss | x3550 management console | On the front of the HMC server, at the far right, near the thumb screw (in a vertical orientation). | Management console (MC) server location codes (Models 961, 951, 941) |
| 7978.mmm.sssssss | x336 management console | On the front of the HMC server, at the far right, near the thumb screw (in a vertical orientation). | Management console (MC) server location codes (Models 961, 951, 941) |
| 4061.mmm.sssssss | ThinkPad W500 laptop management console | On the bottom of the ThinkPad laptop. | Management console (MC) server location codes (Models 961, 951, 941) |
| 4349.mmm.sssssss | ThinkPad T510 laptop management console | On the bottom of the ThinkPad laptop. | Management console (MC) server location codes (Models 961, 951, 941) |
| 4242.mmm.sssssss | ThinkPad T520 laptop management console | On the bottom of the ThinkPad laptop. | Management console (MC) server location codes (Models 961, 951, 941) |